Of attic space equally divided between eave and ridge vents.
Fine homebuilding attic ventilation.
In an attic the primary driving force is the buoyancy of warm air rising in the vault of the roof.
But building scientist joe lstiburek takes issue with that opting instead for more ventilation at the eaves say a 60 40 split with the eaves getting the greater proportion.
As the warm air escapes through vents high on the roof cooler air enters the lower vents.
Of ventilation area 1 sq.
15 articles and videos from the fhb archive that will take you through every step of the roof venting process.
Of vents for each 300 sq.
Codes require a net free ventilation area nfva of 1 sq.
If an attic measures 900 sq.
Intake vents located at the lowest part of the roof under the eaves allow cool.
It s one of the more confusing aspects of home building and.
Slots notched in the top of the timberstrand blocks placed between the tji rafters lets air flow into the ventilation channels from the cor a vent s 400 vent strips installed between the soffit boards.
Ft code requires that there be a minimum of 3 sq.
For every 300 sq.
Attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents.
The baffles will create vent spaces and prevent windwash energy robbing convective short circuiting air moving through the insulation 1 1 4 in.
This way it s not as big a deal if the ceiling leaks air or if the ducts are leaky and uninsulated.
Roofs need a driving force to move air in and out and intake and exhaust vent openings large enough to facilitate this movement.
Attic fans are intended to cool hot attics by drawing in cooler outside air from attic vents soffit and gable and pushing hot air to the outside.
Absent that try to provide at least a net free vent area of all ventilation openings of 1 150th of the horizontal area of the attic with reasonable cross flow to eliminate stagnant pockets of air.
Vent the roof deck.
Ft of ventilation area at the ridge and the remainder at the soffits.
In mixed climates ventilation serves either role depending on the season.
Ft and 50 1 5 sq.
In a hot climate the primary purpose of ventilation is to expel solar heated hot air from the attic or roof to reduce the building s cooling load and to relieve the strain on air conditioning systems.
However if your attic has blocked soffit vents and is not well sealed from the rest of the house attic fans will suck cool conditioned air up out of the house and into the attic.